Owned by: China Association for Science and Technology
Sponsored by: China Coal Society
Published by: Springer Nature
About issue

The International Journal of Coal Science & Technology is a peer-reviewed open access journal. It focuses on key topics of coal scientific research and mining development, serving as a forum for scientists to present research findings and discuss challenging issues.


Coverage includes original research articles, new developments, case studies and critical reviews in all aspects of scientific and engineering research on coal, coal utilizations and coal mining. Among the broad topics receiving attention are coal geology, geochemistry, geophysics, mineralogy, and petrology; coal mining theory, technology and engineering; coal processing, utilization and conversion; coal mining environment and reclamation and related aspects.


The International Journal of Coal Science & Technology is published with China Coal Society, who also cover the publication costs so authors do not need to pay an article-processing charge.


The journal operates a single-blind peer-review system, where the reviewers are aware of the names and affiliations of the authors, but the reviewer reports provided to authors are anonymous.


  • A forum for new research findings, case studies and discussion of important challenges in coal science and mining development

  • Offers an international perspective on coal geology, coal mining, technology and engineering, coal processing, utilization and conversion, coal mining environment and reclamation and more

  • Published with the China Coal Society

Show More
Editors-in-Chief
Suping Peng, Shimin Liu
Managing Editor
Wanjie Wang
Associate Editors
Bo Hyun Kim, Dongjie Xue, Pedram Roghanchi, Wu Xiao, Zhiqiang Wu
Publishing model
Open Access. Learn about publishing OA with us
Home > Volumes and issues > Volume 2, issue 9

Optimization of environmental maintenance system used in a refuge chamber

Research Article

Open Access

Published: 14 November 2015

0 Accesses

International Journal of Coal Science & Technology Volume 2, 312-317, (2015)

Abstract

Mine refuge chambers are used to shield miners who fail to escape from the mine when incidents occur. Environment maintaining system plays a key role in stabilizing thermal environment of a mine refuge chamber against heat emitted from metabolism and transferred from outside. The safety and comfort of refugees are closely related to the environment maintaining system design. In order to improve the comfort of refugees, optimization on the environment maintaining system has been done based on the previous work. To evaluate the environment of the chamber, eight volunteers were involved into the experiment. Under close observation and safety protection, they lived in a heat-isolated test chamber for 106 hours. The volunteers were asked to maintain low level of activities to simulate refugees’ situation. It shows that the environment maintaining system worked well and the temperature, relative humidity and emitted harmful air content such as CO2 and CO were all kept in the safety level, and no discomfort was felt by volunteers at all.

1.Introduction

Mine refuge chambers are used to shield miners who fail to escape from the mine when incidents occur. They should provide breathable air, food, water and a safe environment, which is essential to the refugees.

Mine refuge chamber would be heated and humid due to internal refugees and external underground situation. High levels of heat and humidity could cause sweating, paleness, cramps, tiredness, weakness, dizziness, headache, nausea or vomiting, and fainting. An environment maintaining system includes a refrigerator, a pressure balance system and an air cleaning subsystem. The refrigerator mentioned in previous work is used to control temperature and humidity in the chamber. The pressure balance system is used to keep the internal pressure in a reasonable range. The air cleaning subsystem, also located in the refrigerator, is used to absorb CO2 and CO in the air recycling (Yang and Yang 2013).

The temperature, relative humidity and the concentration of CO2 and CO are important factors that affect the comfort and safety of the refugees

There were a large number of studies about the thermal comfort in offices and work buildings. Memon assessed the thermal comfort within the classroom of a university in subtropical of Pakistan and found that more than 80 % of people were satisfied at an effective temperature of 32.5 °C (Memon et al. 2008). Sander ter Mors et al. investigated the thermal comfort and thermal comfort parameters for children in primary school classrooms. The questionnaires had been applied to obtain the actual thermal sensation and clothing insulation in the morning and afternoon of regular school days (Mors et al. 2011). Noh et al. studied thermal comfort and indoor air quality in lecture room (Noh et al. 2007). Muhi and Butala studied the influence of thermal environment and air quality level on the employees in the mechanical ventilated administrative offices (Muhi and Butala 2004). An examination of thermal comfort in a hospital had been conducted (Pourshaghaghy and Omidvari 2012). Abbritti et al. estimated the value of PMV in sick buildings (Abbritti et al. 1992). Sabrina et al. assessed indoor environment quality for hypermarket workers and found that data collected at fixed point locations showed only minor (and predictable) biases due to expectation and to transition through different thermal environments (Sabrina et al. 2012). Jan et al. made an evaluation of the optimal temperature in each cabin of the Korean maritime patrol vessels and found that the optimum temperature was 23 °C in the wheelhouse and 29 °C in the accommodation (Jan et al. 2007).

All the papers mentioned above focused on the environment of the ordinary buildings. The mine refuge chamber is narrow in space and works in incidents situation. In result of these features, internal environment condition and air quality would be different from previous studies. Jia et al. investigated the refrigerating characteristics of ice melting enclosed in a cube capsule in coal mine refuge chamber (Jia et al. 2015). Jia et al. studied on purification characteristic of CO2 and CO within closed environment of coal mine refuge chamber by mean of the simulation device (Jia et al. 2014). In this paper, the performance of the environment maintaining system is examined.

2.Experiment description

In the experiment, a full-size heat isolated chamber was built, and eight volunteers lived in the chamber for 106 hours under close observation and safety protection. Their age ranges from 18 to 35, and they had the same wearing. During the experiment, they could only consume food and water prepared in the chamber and the door of the chamber was kept closed. If any discomfort was felt or the volunteers were in danger, the door could be opened from both inside and outside. The volunteers had breakfast regularly at 8:00 am, lunch at 12:00 am and supper at 5:00 pm. In most of duration, they were asked to maintain low level of activities. It is shown in Fig. 1 that the volunteers were sitting in the chamber.

Fig. 1
figure 1

Persons sitting in the chamber

Figure 2 is the photo of the refrigerator and air cleaning subsystem. Figure 2a is the previous one and Fig. 2b is the present design. The present one is a compacter design and the air flow distributes more non-uniformly. The refrigerators are open cycle because the compressor should not be used in a coal mine. On the one hand, in most situations the electric power supply breakdown will occur at an accident, and the refrigerator will fail to run. On the other hand, the compressor is located outside of the refuge chamber, and could be damaged by gas explosions that often occur in underground coal mines (Fang et al. 2012; Zhao and Qian 2012; Zhao et al. 2012).

Fig. 2
figure 2

Refrigerator and air cleaning subsystem. a The previous, b the present

Both of the refrigerators include four rooms. The air outlet is aligned differently in position to the four rooms. Once the air in the chamber goes into the cabinet, it will travel in such a sequence: Firstly, air with ambient temperature is inhaled into the cabinet at the bottom, and then goes through the condensed water room. After reducing humidity air goes through the CO2 absorption room and the CO absorption room in sequence, where CO2 and CO is absorbed. Then, the air goes through evaporator and is cooled down as a result. Finally, low temperature and breathable air is blown out from the cabinet into the chamber.

The personnel activity was observed by a camera in real time, and the experiment data of temperature, relative humidity, CO2 concentration and CO concentration in the chamber were recorded by the computer.

Three thermometers (Tr1, Tr2 and Tr3) were arranged in the chamber evenly in heights, see Fig. 3. The relative humidity sensors, CO2 concentration sensors, CO concentration sensors, O2 concentration sensors and gauge pressure sensors were at the same location of the three thermometers. The dates were recorded every 30 min. The dates in the follow figs were measured values by the sensors.

Fig. 3
figure 3

Arrangement of the sensors

All the sensors used in the experiment were calibrated. The temperature was measured by pt100 thermometers with an accuracy of ±0.1 °C, and the corresponding relative humidity is measured by JWSK-6 with accuracy of ±0.5 °C (−20 to 60 °C), ±3 %RH (5 %RH–95 %RH) made by a corporation named Collihigh in China. The pressure in the experiment is measured by MEAS pressure sensors calibrated with a standard pressure source with accuracy of ±0.25 % BSL, max(combined linearity, hysteresis & repeatability). The CO concentration, CO2 concentration and O2 concentration were measured by sensors with accuracy of ±2 %, ±0.1 % and ± 3 %, respectively.

3.Experimental results and discussions

3.1 Temperature and relative humidity in the chamber

Figures 4 and 5 are the temperature and relative humidity in the chamber. Internal temperature increased sharply after volunteers’ entering. The heat from volunteers’ metastasis warmed internal air up to 30 °C. Because they were in exciting or anxious mood, depending on their different psychological status, the amount of diffused heat was very large at this stage. After they calmed down gradually, the temperature decreased to an ordinary level and varied via time. Normally, the temperature ranged between 25 and 28 °C and the relative humidity ranged between 50 % and 70 %. When they had dinner, the temperature would increase to the maximum of 30 °C, while the relative humidity increases to 75 %. On contract, the temperature would drop down to the minimum of 23 °C with a relative humidity of 45 % when they were sleeping. It is shown that level of personnel’s activity impact internal temperature and relative humidity greatly in such a narrow space. Position of Tr2 was located towards the cold air flow, which resulted a low reading than Tr1 and Tr3.

Fig. 4
figure 4

Temperature varies with time in the chamber

Fig. 5
figure 5

Relative humidity varies with time in the chamber

3.2 CO2 and O2 concentration in the chamber

The concentration of CO2 and O2 are 1 % and 21 % respectively in atmosphere. Regarding the complex situation in the refuge chamber, the concentration might change, but should stay in breathable level. So the extra CO2 should be absorbed by the air cleaning system. Figure 6 illustrates the CO2 concentration in the 106 h. The concentration varied between 0.2 % and 0.7 % and remained stable, nearly 0.5 %, most of the time. This means the absorption capability is enough for 8 personnel. In this result, it also could be seen that the concentration was lower in the middle than the other two positions due to a better convection situation.

Fig. 6
figure 6

CO2 concentration varies with time in the chamber

The O2 is supplied by the O2 cylinders placed in the chamber before the experiment. The flow rate of the O2 is controlled by a throttle. Figure 7 is the concentration of O2 in the chamber. It ranged from 19.5 % to 22 %. From the data above, it could be seen that the air in the closed chamber has almost the same content as the atmosphere, which ensures the personnel’s safety.

Fig. 7
figure 7

O2 concentration varies with time in the chamber

3.3 Pressure in the chamber

Tinnitus, chest distress and poor breath might happen when persons are living in an environment with too high or too low pressure. The pressure balance system is designed to maintain a suitable pressure in the chamber by supplying and relieving air when the pressure is below −200 Pa and over 600 Pa. Figure 8 shows the gauge pressure in the chamber. It could be seen that the gauge pressure varied round 300 Pa in the range of 150–450 Pa. The sensors at the three positions had almost the same reading. Due to this pressure balance system, no discomfort was felt during the experiment.

Fig. 8
figure 8

Gauge pressure varies with time in the chamber

3.4 CO concentration in the chamber

High concentration of CO might lead to CO poisoning. CO is rarely produced in human’s metabolism, in case of incidental accumulation, CO absorbing function is designed to active automatically according to CO concentration. Figure 9 is the CO concentration during the experiment. The concentration of the CO was zero in the first 30 h and CO absorbing function was off. When small amounts of CO was produced by metabolism and accumulated up to 4 × 10−6 g/mL at maximum, the CO absorbing function was triggered on automatically. After 30 min, CO concentration reduced. During this period the volunteers did not feel uncomfortable at all.

Fig. 9
figure 9

CO concentration varies with time in the chamber

In summary, the environment maintaining system functions as follow: air in the chamber is inhaled into the cabinet, the pollution in the air is absorbed and the air is cleaned and cooled down in the refrigerator, then cool and fresh air is blown out. The environment maintaining system provides a fundamental environment for human’s living. According to the experiment above, all the functionality of the system ran well and no discomfort was felt in the duration of 106 hours. This means the system has the capability to provide a good environment for life maintenance in case of incidents. To improve personnel’s comfort, the flow around the human body would be further analyzed.

4.Conclusions

The environment maintaining system was optimized and tested when eight volunteers living in. The experiment results showed the conclusions as follow:

  1. (1)

    The system could control the temperature between 25 and 28 °C and the relative humidity was between 50 % and 70 %, which were the comfortable range for human being.

  2. (2)

    The CO2 concentration varied between 0.2 % and 0.7 % and stayed nearly 0.5 %, which was the same as the air content and was safe.

  3. (3)

    The O2 concentration ranged from 19.5 % to 22 % and was suitable for breathing.

  4. (4)

    The gauge pressure was controlled in the range of 150 to 450 Pa.

All the parameters were within the safety range, and no discomfort was felt. This meant the optimizing of the environmental maintaining system was reasonable and was useful for the design of the chamber.

References

[1] Abbritti G, Muzi G, Accattoli MP, Fiordi T, Dell’Omoa M, Colangelia C, Gabriellia AR, Fabbria T, D’Alessandro A (1992) High prevalence of sick building syndrome in a new air conditional building in Italy. Arch Environ Health 47(1):16–22
[2] Fang HF, Ge SR, Cai LH, Hu EY (2012) Buckling analysis of the shell of a refuge chamber in a coal mine under uniform axial compression. Int J Min Sci Technol 22(1):85–88
[3] Jan MS, Koh CD, Moon IS (2007) Review of thermal comfort design based on PMV/PPD in cabins of Korean maritime patrol vessels. Build Environ 42(1):55–61
[4] Jia YX, Liu YS, Liu WH, Li ZY (2014) Study on purification characteristic of CO2 and CO within closed environment of coal mine refuge chamber. Sep Purif Technol 130(10):65–73
[5] Jia YX, Liu YS, Sun SF, Li HY, Jiao LL (2015) Refrigerating characteristics of ice storage capsule for temperature control of coal mine refuge chamber. Appl Therm Eng 75(22):756–762
[6] Memon RA, Chirarattananon S, Vangtook P (2008) Thermal comfort assessment and application of radiant cooling: a case study. Build Environ 43(7):1185–1196
[7] Muhi S, Butala V (2004) The influence of indoor environment in office buildings on their occupants, expected–unexpected. Build Environ 39(3):289–296
[8] Noh KC, Jang JS, Oh MD (2007) Thermal comfort and indoor air quality in the lecture room with 4-way cassette air-conditioner and mixing ventilation system. Build Environ 42(2):689–698
[9] Pourshaghaghy A, Omidvari M (2012) Examination of thermal comfort in a hospital using PMV–PPD model. Applied Ergon 43(6):1089–1095
[10] Sabrina DC, Francesco M, Antonio S (2012) A measurement procedure to assess indoor environment quality for hypermarket workers. Build Environ 47:288–299
[11] Mors S, Hensen JL, Loomans MG, Boerstra AC (2011) Adaptive thermal comfort in primary school classrooms: creating and validating PMV-based comfort charts. Build Environ 46(12):2454–2461
[12] Yang JL, Yang LW, Wei J, Ma YZ, Zhang ZT (2013) Study on open cycle carbon dioxide refrigerator for movable mine refuge chamber. Appl Therm Eng 52(2):304–312
[13] Zhao HJ, Qian XM (2012) Simulation analysis on structure safety of two typical refuge chamber shell forms under explosion load. Procedia Eng 45:910–915
[14] Zhao HJ, Qian XM, Li J (2012) Simulation analysis on structure safety of coal mine mobile refuge chamber under explosion load. Saf Sci 50(4):674–678

Funding

This research was supported by the Natural Science Foundation of Jiangsu Province (BK20140274); the Director Foundation of Institute of Physics and Chemistry, CAS (2014-yjl) and Xinjiang “125” Major Projects (201130112).

About this article

Cite this article

Yang, J., Yang, L., Zhang, C. et al. Optimization of environmental maintenance system used in a refuge chamber.Int J Coal Sci Technol 2, 312–317 (2015).
  • Received

    24 March 2015

  • Revised

    29 April 2015

  • Accepted

    28 July 2015

  • Issue Date

    December 2015

  • DOI

    https://doi.org/10.1007/s40789-015-0090-1

  • Share this article

    Copy to clipboard

For Authors

Explore