The International Journal of Coal Science & Technology is a peer-reviewed open access journal. It focuses on key topics of coal scientific research and mining development, serving as a forum for scientists to present research findings and discuss challenging issues.
Coverage includes original research articles, new developments, case studies and critical reviews in all aspects of scientific and engineering research on coal, coal utilizations and coal mining. Among the broad topics receiving attention are coal geology, geochemistry, geophysics, mineralogy, and petrology; coal mining theory, technology and engineering; coal processing, utilization and conversion; coal mining environment and reclamation and related aspects.
The International Journal of Coal Science & Technology is published with China Coal Society, who also cover the publication costs so authors do not need to pay an article-processing charge.
The journal operates a single-blind peer-review system, where the reviewers are aware of the names and affiliations of the authors, but the reviewer reports provided to authors are anonymous.
A forum for new research findings, case studies and discussion of important challenges in coal science and mining development
Offers an international perspective on coal geology, coal mining, technology and engineering, coal processing, utilization and conversion, coal mining environment and reclamation and more
Published with the China Coal Society
Research Article
Open Access
Published: 23 July 2019
0 Accesses
International Journal of Coal Science & Technology Volume 6, 445-458, (2019)
1.
Department of Chemical Engineering, Indian Institute of Technology (IIT) Kharagpur, Kharagpur, India
2.
Department of Chemical Engineering, Indira Gandhi Institute of Technology (IGIT) Sarang, Sarang, India
3.
Department of Chemical Engineering, School of Chemical Engineering, Howard College Campus, University of Kwazulu-Natal (UKZN), Durban, South Africa
Carbon dioxide (CO2) is the major component of greenhouse gas. Increase in concentration of CO2 in the atmosphere leads to global warming. To remove the CO2 from waste flue gas a four-stage counter-current multistage fluidized bed adsorber was developed and operated in continuous bubbling fluidization regime for the two-phase system. This paper describes the optimum condition for CO2 removal efficiency in a multistage fluidized bed reactor using amine impregnated activated carbon. Response surface methodology with central composite design was used to determine the effect of three variables on the response. The variables are inlet concentration of CO2 in ppm (ranging from 3000 to 20,000), impregnation ratio of monoethanol amine (ranging from 0.2 to 0.6) and weir height in mm (20–60). The response was CO2 removal efficiency. The factor which was most influential has been identified from the analysis of variance. The optimum CO2 removal efficiency for the amine impregnated activated carbon (MEA-AC) was found to be 95.17%, at initial concentration of CO2 7312.85 ppm, chemical impregnation ratio of 0.31, and weir height 48.65 mm. From the experiment, the CO2 removal efficiency was found to be 95.97% at the same operating conditions. The predicted response was found to relevance with experimental data.
Now a day’s due to rapid industrialization and lots of human activities large amount of greenhouse gases are emitted into the environment. The major contributor for global warming is caused by increase in percentage (%) of CO2 in the atmosphere. The release of CO2 mainly comes from burning of fossil fuels i.e. coal, oil and natural gas that leads to increase in CO2 emissions and as a result of which, CO2 concentrations in the atmosphere increases. Increase of CO2 concentration leads to trapping of more heat near the surface of the earth. The main disadvantage is the collapse of the ecosystem which lead to more draughts, floods and other extreme weather. To overcome these phenomena CO2 capture technologies, like absorption, adsorption, cryogenics, and membranes separation technology have been investigated (White et al. 2003; Aaron and Tsouris 2005). The most developed technology is the amine-based absorption process (Bai and Yeh 1997; Yeh and Bai 1999; Rao and Rubin 2002). The major disadvantages associated with this process is corrosion of the process equipment (Hsu et al. 2010) and also this process is energy intensive. Due to serious drawbacks of this process, alternative energy-efficient separation techniques (Arenillas et al. 2005; Gray et al. 2004a, b, 2005) was developed. By taking into the above consideration adsorption is seems to be the most cost effective techniques. So various researchers have studied the development of adsorbent that is easily regenerated and have sufficient strength for high CO2 selectivity and adsorption capacities (Xu et al. 2002a, b; Drage et al. 2007). Activated carbons (ACs) have high adsorption capacity, regeneration is easier, and highly hydrophobic nature and low cost and can be easily manufactured (Das et al. 2015; Plaza et al. 2010). From the literature, it has been studied that the CO2 capture capacity can be increased by chemical impregnation (Alvim-Ferraz and Gaspar 2005; Lach et al. 2006; Adamski et al. 2007; Bowker et al. 2007; El-Molla et al. 2007; Xu et al. 2002a, b; Gray et al. 2004a, b; Przepiórski et al. 2004; Das et al. 2016a, b, 2017; Das and Meikap 2018, 2019) i.e. by incorporation of amine functional group.
In our present work, green coconut shell based AC has been prepared because it is considered superior to those obtained from other sources mainly due to small macrospores structure which renders it more effective for the adsorption of gas/vapour and it has high fixed carbon and low ash content (Das et al. 2015) and it has been impregnated with monoethanol amine solution (MEA) for removal of CO2 in a multistage fluidized bed reactor. MEA-AC shows high % removal of CO2 because of formation of primary zwitterions in reaction chemistry with CO2 which was more stable due to inductive effect (Das and Meikap 2019). Multistage fluidized bed reactor with down comer is the most suitable air pollution control equipment for the removal of gaseous pollutants from the industrial flue gas (Mohanty et al. 2008, 2010; Roy et al. 2009; Das et al. 2016a, b, 2017; Das and Meikap 2017, 2018, 2019).
Limited study has been carried out on optimization for the CO2 removal efficiency (%) in a multi-stage fluidized bed reactor by amine impregnated AC using RSM approach. The influence of operating parameters, such as inlet concentration of CO2, impregnation ratio of the adsorbents and weir height were investigated in fluidized bed reactor and for process optimization. Statistical experimental design methods have been used. To understand the interaction among the parameter and to build statistical model, the experimental design technique is a very useful tool and it describes the condition under which the process parameters have been optimized (Alam et al. 2007). Among different design methods, the most suitable method is RSM. The main advantage is that RSM based on CCD helps for optimization of the effective parameter and the number of experiments were minimum. It is suitable for fitting a quadratic surface and steps are development of experimental design matrix, building of model and find the optimum region that satisfies the operating specifications (Montgomery 2001). In this paper, optimization framework with surface response methodology is developed to minimize the cost of CO2 removal for the amine-based adsorbent in multistage fluidized bed reactor.
In the present experiment, the raw material was green coconut shell. It was collected from nearby local market of IIT Kharagpur, India., followed by washing with normal tap water so that all the dust and adhere impurities were to be removed and then cut into small pieces then dried in sun light for 20–25 days till it completely dry. The dried materials were put in an oven for 48 h at 105 °C for removal of moisture. After oven dried the shells were grounded by locally made grinder and then it was sieved to a size 512 µm.
The powder precursor was chemical activated with Zinc chloride (ZnCl2). 1 kg of powder material was well mixed with 1 kg of Zinc chloride (ZnCl2) solution in the impregnation ratio (activating agent/precursor) 1:1. Then the impregnated sample was kept for 24 h for proper soaking of chemicals onto the surface of the precursor. The resulting mixture was kept in an air oven and dried for 36 h at 105 °C. The chemical impregnated samples were put inside the muffle furnace by placing in a box made up of stainless steel and heated (10 °C/min) up to the final carbonization temperature of 650 °C under 120 mL/min nitrogen gas flow rate at STP. Samples were held at 650 °C for 1 h. Then it was cooled down under nitrogen gas. The final carbonized samples were washed with 0.5 N HCl, then with hot water and finally washed with cold distilled water for removal of mineral matters and residual organic. Finally the prepared sample was then dried at 105 °C in an air oven till it was completely dry.
Twenty sets of dried carbonized powder precursor samples were impregnated with monoethanol amine solution (MEA) at different impregnated ratio (0.2, 0.3, 0.4, 0.5, and 0.6) and kept in an air tight container for further experiment.
The adsorbent used for removal of CO2 in our experimental set up was monoethanolamine impregnated AC. The adsorbent was characterized by Proximate and Ultimate Analysis, Thermo Gravimetric Analysis (TGA), Scanning Electronic Microscope (SEM), Energy-Dispersive X-ray Spectroscopy (EDX), Fourier Transfer Infrared Spectroscopy (FTIR), X-Ray Diffraction (XRD), Accelerated Surface Area and Porosimetry analyzer (ASAP2020).
RSM along with CCD was used to determine the relationship between three operating variables and the response i.e. for removal efficiency of CO2 in a multistage fluidized bed reactor. CCD was used for second order model. This method is suitable for fitting a quadratic surface and it helps to optimize the effective parameters with a minimum number of experiments, and also to analyze the interaction between the parameters (Azargohar and Dalai 2005). The first step was formation of design matrix. It consists of a 2n factorial points, 2n axial points and nc center points (six replicates) (Myers 1971; Napier-Munn 2000). The functions of axial points are that it allows rotatability (Box and Hunte 1957). The functions of center points are evaluation of the experimental error and the reproducibility of data (Sahu et al. 2008, Sahu et al. 2009a, b). An empirical model was developed and the response was correlated to the adsorption of CO2 process variables using a second-degree polynomial equation as given by the following Eq. (1) (Can et al. 2006; Gönen and Aksu 2008).
where Y is the predicted response, \(\beta_{0 }\) is the constant coefficient, \(\beta_{i}\) is the linear coefficients, \(\beta_{ii}\) is the interaction coefficients, \(\beta_{ij}\) is the quadratic coefficients and \(X_{i,} X_{j}\) are the coded values of the removal efficiency of CO2 by MEA-AC in a multistage fluidized bed reactor. \(\varepsilon\) is the random error. n is the number of factor studied.
For three variables (n), the total number of tests (N) required is 20 (Box and Hunter 1961). It consisting of 8 factorial points, 6 axial points and 6 replicates at the centre points were employed, indicating that altogether 20 experiments were required, as calculated from Eq. (2) (Azargohar and Dalai 2005).
The coded variables for factorial points are lie at ± 1 and ± α for the axial points and 0 for the center points.
The Design-Expert software version 7.0.0 was used for regression analysis of experimental data to estimate the statistical parameters.
The schematic diagram of four staged fluidized bed reactor was shown in Fig. 1. The fluidized bed column was consisted of four stages (0.21 m height per stage and 0.095 m internal diameter). Stages were assembled together with flanged joint. In between the stages of the fluidized bed reactor four number of stainless steel made plate (S1, S2, S3, S4) of 0.002 m thick were used and it was drilled with hole of diameter 0.002 m. A fine weir mesh (100 mesh size) was there on the grid plate to avoid the solids were falling down through the plate, down comers (D1, D2, D3, D4) of 0.024 m internal diameter and height of 0.265 m and it made up of Perspex cylinder. Each section was provided with down-comers and it was further fitted with a cone of diameter 0.007 m and 0.024 m height at the bottom end so that the up-flow of the gas through the down-comer was reduced to maintain stable operation. The down-comers were further fitted to the gas distributor by some threading arrangement to adjust the weir height as required.
The weir height is considered to be bed height. The material flows from stage to stage through the down-comer. There were provisions for measuring pressure drop. For uniform distribution of the gas to the fluidization column, gas distributor was there at the bottom of the column. Calibrated rotameter was fitted to measure the air flow rate. For storage of the solid coming from the fluidized bed column a conical hopper was attached. A feeding funnel was there at the top of the column to hold the amine impregnated activated carbon particles and it was attached to the screw feeder. Screw feeder was fitted to a motor of 0.25 HP and the speed of the motor was controlled by a variable rheostat. Compressor was used to supply the air as fluidizing gas having capacity 5HP. The solid fed to the first stage of the down-comer from the top of the funnel connected to screw feeder and then through Perspex tube (0.011 m internal diameter). The gas leaving the top stage is passed through 0.14 m diameter cyclone. To collect the fines coming out from the fluidized bed, a bag is attached to the bottom of the cyclone. There was provision to feed the air-CO2 mixture at the bottom of the fluidized bed reactor from in the mixing chamber. The air should not be enter into the column. The experiments were conducted by setting the gas velocity of 0.188 m/s corresponding to solid flow rate of 4.12 kg/h. The experiment was conducted at normal room temperature. The experimental variables are considered as chemical impregnation ratio ranging from 0.2 to 0.6, the inlets CO2 loadings concentration were varied from 3000 to 20,000 ppm and weir height 20 to 60 mm. Since those parameters were important parameters that affects the CO2 removal efficiency (%) by amine impregnated activated carbon particles in a fluidized bed reactor.
When all stages of the reactor were identical in their operation and the pressure drops across each stage were almost equal, then it indicated steady and stable operation reactor. At that time samples at the inlet and outlet of the column were drawn with the help of aspirator bottles and the obtained CO2 gas samples were analyzed by Orsat analysis. The gas samples i.e. concentration of CO2 in CO2 + air mixture were analyzed for CO2 by the “Orsat Analysis” method. Aspirator bottle filled with kerosene; one end of the bottle was fitted below the inlet section of the first stage fluidized bed reactor through a pipe and the other end is connected to the collecting jar. By downward displacement of kerosene CO2 + air mixture has been collected into the aspirating bottles. Then this air and CO2 mixture from aspirating bottle was taken inside Orsat apparatus. By noting the level difference of initial and final marking of measuring burette the volumetric percentage of concentration of CO2 has been found out and then the volumetric concentration of CO2 was converted to ppm.
Figure 2 shows the Orsat apparatus. It consists of measuring burette and absorption pipette. Measuring burette was connected to leveling bottle which contains a mixture of potassium dichromate, water, and sodium chloride. Absorption pipette contains potassium hydroxide which absorbs CO2. Figure 3 shows the aspirator bottle. The aspirator bottle was used to collect and analyze CO2 gas sample. First the mixture of solution (potassium dichromate, sodium chloride, water) in measuring burette is adjusted as 100 ml using a leveling bottle by opening and closing the inlet valve. The potassium hydroxide level in adsorption pipette was recorded, and then one end of aspirator bottle was connected to the capillary tube and the other end is connected to the leveling bottle that contains kerosene. The valves of aspirator bottle and inlet valve were opened. After lifting the water bottle, the reading in burette decreases as CO2 enters into the burette simultaneously. When the reading reaches zero, the inlet valve was closed. The absorption pipette valve was opened, and then the leveling bottle is adjusted for 30–50 times till all the CO2 gas samples are absorbed in the KOH. After that the valve was closed and the final reading was noted. The change in reading gives the volume % of CO2 absorbed by the KOH solution. Then it was converted to ppm.
The CO2 removal efficiency (%) has been calculated for each experimental run by Eq. (3)
where Ci and Ci+1 are outlet and inlet CO2 concentrations in gas.
Design expert software has been used for analysis of experimental data by development of regression model equation. Central composite design (CCD) was used to develop correlation between the CO2 removal efficiency (%) and the independent variables. The purpose of Response Surface Methodology (RSM) is to analyze the interaction between the parameters and also to optimize the effective parameters with a minimum number of experiments (Azargohar and Dalai 2005). Table 1 shows the relationship between coded and actual value of the variables. The levels and experimental range of independent variables are given in Table 2. The quadratic model was selected as suggested by the software. The design matrix along with response of this experiment was given in Table 3. There are six replicates at the center point. To fit the response function of the CO2 removal efficiency (%), regression analysis was performed. The final empirical model in terms of coded factors for CO2 removal efficiency (%) (Y) Is given in Eq. (5),
Code | Actual level of variable |
---|---|
− α | X min |
− 1 | [(Xmax + Xmin)/2] − [(Xmax − Xmin)/2β] |
0 | (Xmax + Xmin)/2 |
+ 1 | [(Xmax + Xmin)/2] + [(Xmax − Xmin)/2β] |
+ α | X max |
Variables | Symbol | − α | − 1 | 0 | + 1 | + α |
---|---|---|---|---|---|---|
Inlet concentration of CO2 (ppm) | X1 | 3000 | 7250 | 11,500 | 15,750 | 20,000 |
Impregnation ratio (IR) (g/g) | X2 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 |
Weir height (mm) | X3 | 20 | 30 | 40 | 50 | 60 |
Coded level of variables | Actual level of variables | CO2 removal efficiency (%) | |||||
---|---|---|---|---|---|---|---|
Run | X 1 | X 2 | X 3 | X1 (ppm) | X2 (wt%) | X3 (mm) | |
1 | − 1 | − 1 | − 1 | 7250 | 0.3 | 30 | 93.96 |
2 | + 1 | − 1 | − 1 | 15,750 | 0.3 | 30 | 86.32 |
3 | − 1 | + 1 | − 1 | 7250 | 0.5 | 30 | 89.95 |
4 | + 1 | + 1 | − 1 | 15,750 | 0.5 | 30 | 85.72 |
5 | − 1 | − 1 | + 1 | 7250 | 0.3 | 50 | 94.96 |
6 | + 1 | − 1 | + 1 | 15,750 | 0.3 | 50 | 89.82 |
7 | − 1 | + 1 | + 1 | 7250 | 0.5 | 50 | 90.13 |
8 | + 1 | + 1 | + 1 | 15,750 | 0.5 | 50 | 87.93 |
9 | − α | 0 | 0 | 3000 | 0.4 | 40 | 94.07 |
10 | + α | 0 | 0 | 20,000 | 0.4 | 40 | 80.97 |
11 | 0 | − α | 0 | 11,500 | 0.2 | 40 | 89.22 |
12 | 0 | + α | 0 | 11,500 | 0.6 | 40 | 82.63 |
13 | 0 | − 0 | − α | 11,500 | 0.4 | 20 | 89.27 |
14 | 0 | 0 | + α | 11,500 | 0.4 | 60 | 93.63 |
15 | 0 | 0 | 0 | 11,500 | 0.4 | 40 | 91.66 |
16 | 0 | 0 | 0 | 11,500 | 0.4 | 40 | 91.56 |
17 | 0 | 0 | 0 | 11,500 | 0.4 | 40 | 91.63 |
18 | 0 | 0 | 0 | 11,500 | 0.4 | 40 | 91.58 |
19 | 0 | 0 | 0 | 11,500 | 0.4 | 40 | 91.32 |
20 | 0 | 0 | 0 | 11,500 | 0.4 | 40 | 91.59 |
In the above correlation, the CO2 removal efficiency (%) (Y) is the function of inlet concentration of CO2 (X1), impregnation ratio (X2) and weir height (X3). From their coefficient of correlation, quality of the model was judged.
Table 4 shows the analysis of variance (ANOVA) for CO2 removal efficiency (%). The model adequacy check was done by seeing to residual plots by approximating model (Box et al. 1978). The studentized residuals measure the number of standard deviations separating the actual and predicted values. The normal probability and studentized residuals plot is shown in Fig. 4. Figure 5 shows the studentized residuals verses predicted CO2 removal efficiency (%). This plot exhibited a funnel-shaped pattern (Mahalik et al. 2010; Sahu et al. 2009a, b, 2010; Myers and Montgomery 2002) due to the variance of the response depends on the mean level of Y. The actual and the predicted CO2 removal efficiency (%) are shown in Fig. 6. This indicates that there was no need for transformation of the response variable.
Source | Sum of squares | Degree of freedom | Mean square | F value | Prob > F | Remarks |
---|---|---|---|---|---|---|
Model | 251.68 | 9 | 27.96 | 47.07 | < 0.0001 | Significant |
X 1 | 128.88 | 1 | 128.88 | 216.93 | < 0.0001 | Significant |
X 2 | 37.55 | 1 | 37.55 | 63.2 | < 0.0001 | Significant |
X 3 | 15.23 | 1 | 15.23 | 25.63 | 0.0005 | Significant |
X 1 X 2 | 5.04 | 1 | 5.04 | 8.48 | 0.0155 | Significant |
X 1 X 3 | 2.57 | 1 | 2.57 | 4.32 | 0.0644 | |
X 2 X 3 | 0.56 | 1 | 0.56 | 0.94 | 0.3559 | |
X 21 | 22.32 | 1 | 22.32 | 37.58 | 0.0010 | Significant |
X 22 | 45.22 | 1 | 45.22 | 76.11 | < 0.0001 | Significant |
X 23 | 0.041 | 1 | 0.041 | 0.068 | 0.7989 | |
Residual | 5.94 | 10 | 0.59 | |||
Lack of fit | 5.87 | 5 | 1.17 | 79.57 | < 0.0001 | Significant |
Pure error | 0.074 | 5 | 0.015 | |||
Cor Total | 257.62 | 19 |
Table 5 shows the statistical parameter obtained from the analysis of variance (ANOVA) for the model for CO2 removal efficiency (%). The values of R2 was found to be 0.98, which close to unity and \(R_{{\;\;{\text{adj}}}}^{2}\) was 0.96. It shows that there is a good agreement between the experimental and the predicted values from the model. The predicted R2 value is 0.81. The standard deviation was 0.77. It shows that the model was better and gives the predicted values that closer to the actual values for the response. F-value 47.07 shows the model was significant. The probability value less than 0.05 would be considered with a significant effect. Table 4 shows that X1 (initial concentration of CO2), X2 (impregnation ratio), X3 (weir height), X1X2 (interaction term), X 21 , X 22 are all significant model terms and X1X3 and X2X3 were insignificant term. The value of 79.57 for the “Lack of Fit F-value” implies that Lack of Fit is significant relative to the pure error. Experimental values were very close to the predicted values that indicate the developed model was successful in capturing CO2 in a multistage fluidized bed reactor.
SD | 0.77 |
Mean | 89.9 |
C.V.(%) | 0.86 |
PRESS | 48.06 |
R 2 | 0.98 |
Adjusted R2 | 0.96 |
Predicted R2 | 0.81 |
Adeq precision | 23.92 |
Based on the ANOVA results obtained, inlet concentration of CO2, impregnation ratio of the adsorbent and weir height were found to have significant effects on CO2 removal efficiency(%). Impregnation ratio and initial concentration of CO2 imposing the greatest effect on CO2 removal efficiency (%) in a multistage fluidized bed reactor. Weir height on the other hand imposed moderate effect on the response. The quadratic effects are impregnation ratio and initial concentration and the interaction effect X1X2 are significant and X1X3, X2X3, were considered moderately significant. The response surface graphs of CO2 removal efficiency (%) are shown in Figs. 7, 8 and 9.
Figure 7 shows the combined effect of impregnation ratio (X2) and inlet CO2 concentration (X1) on CO2 removal efficiency (%) at constant weir height of 40 mm. A maximum CO2 removal efficiency was 94.07% and that was determined at constant weir height. When the impregnation ratio of the adsorbent increases the CO2 removal efficiency (%) was also increases progressively and with increase in inlet concentration of CO2, the CO2 removal efficiency (%) decreases because due to an increase in concentration on the surface of amine impregnated activated carbon particle and formation of monolayer which results in decrease of the adsorbent activity (Das et al. 2016a, b; Das and Meikap 2018, 2019).
The combined effect of inlet CO2 concentration (X1) and weir height (X3) on CO2 removal efficiency (%) at constant impregnation ratio is shown in Fig. 8. In the three dimensional response surfaces, the maximum CO2 removal efficiency (%) was 94.07% and was determined at constant impregnation ratio 0.4. From the Fig. 8. It was observed that with increase in weir height the CO2 removal efficiency (%) increases because with increase in the weir height CO2 removal efficiency (%) increases due to increase in bed volume resulting in more gas solid interaction. However, the effect of weir height at lower concentration was not as much as observed at higher concentration indicating the presence of less quantity of reactive solids at lower height (Das et al. 2016a, b; Das and Meikap 2018, 2019).
Figure 9 shows the three dimensional response surfaces which was constructed to show the most important two variables (impregnation ratio and weir height) on the CO2 removal efficiency (%) at constant inlet concentration. Maximum CO2 removal efficiency was 93.63% was determined at constant CO2 inlet concentration 11,500 ppm. From the Fig. 9 it was shown that with increase in impregnation ratio and weir height, the CO2 removal efficiency (%) increases (Das and Meikap 2018, 2019).
To maximize the CO2 removal efficiency (%), the optimum process parameters in a multi stage fluidized bed reactor and development of mathematical model equation have been found out. The quadratic model equation was optimized to maximize the CO2 removal efficiency (%) within the experimental range studied. Optimal processing conditions from numerical optimization were given in Table 6. The contour plot was shown in Fig. 10 and it shows the optimum region on the inlet concentration of CO2 and impregnation ratio for the CO2 removal efficiency (%). Figure 11 shows the 3D plot showing the optimum region for the combined effect of inlet concentration of CO2 and impregnation ratio for the CO2 removal efficiency (%). The optimum production conditions were initial CO2 concentration 7312.85 ppm, impregnation ratio 0.31 and weir height 48.65 mm and have been determined as optimum levels of the process parameters to achieve the maximum CO2 removal efficiency 95.17%. From the experiment it was found that for the same operating condition the CO2 removal efficiency was 95.97%. After comparison the experimental and predicted result, it can be seen that the error between the experimental and predicted result was nearly same.
Parameters | Inlet concentration of CO2 (ppm) | Impregnation ratio (g/g) | Weir height (mm) | CO2 removal efficiency (Y) (%) | |
---|---|---|---|---|---|
Predicted | Experimental | ||||
Optimum condition | 7312 | 0.31 | 48.65 | 95.17 | 95.97 |
Different characterization techniques like Proximate Analysis, Ultimate Analysis, Accelerated Surface Area and Porosimetry analyzer (ASAP2020), Scanning Electronic Microscope (SEM), Fourier Transfer Infrared Spectroscopy (FTIR) and X-Ray Diffraction (XRD) have been used for analysis of the prepared activated carbon under optimum condition. From the proximate analysis it has been seen that, the carbon content of AC and MEA-AC was very high as compared to raw precursor. From the Ultimate analysis, it has been seen that the nitrogen content of MEA-AC sample under optimum condition was more as compared to activated carbon and the raw precursor (i.e. 7.72%), which results in better adsorbents for adsorption purpose. The results of the proximate and ultimate analysis is shown in Table 7. From the Brunauer–Emmet–Teller (BET) analysis, the surface area of MEA-AC prepared under optimum condition was found to be 572.27 m2/g. The pore size distribution was determined by using Barrett–Joyner–Halenda (BJH) model and the t plot determines the volume of the micropore and found to be 0.259 cm3/g. The pore structure parameter of the amine impregnated AC sample under optimum condition is shown in Table 8. Due to amine impregnation the surface area decreases as compared to AC and creates so many of active sites for CO2 capture. From SEM analysis it has been seen that pores are not clearly visible in case of MEA-AC. The SEM micrograph of MEA-AC under optimum condition is shown in Fig. 12. This signifies the pores are filled with impregnated solvent. The FTIR spectra of MEA-AC under optimum condition is shown in the Fig. 13. From the FTIR analysis it has been seen that, all kinds of functional groups and amine functional groups are present in amine impregnated activated carbon. X-ray Diffraction graph shows the absence of any sharp peaks in amine impregnated AC. That concludes the structure is predominantly amorphous in nature and hence got advantageous property for well-defined adsorbent. The XRD graph of the sample is shown in the Fig. 14.
Sample | Proximate analysis | Ultimate analysis | |||||||
---|---|---|---|---|---|---|---|---|---|
Moisture (%) | Volatile matter (%) | Ash (%) | Fixed carbon (%) | C (%) | H (%) | N (%) | O (%) | S (%) | |
RAW | 13.83 | 44.97 | 2.56 | 38.64 | 46.18 | 9.41 | 0.99 | 33.38 | 10.04 |
AC | 12.98 | 7.21 | 1.90 | 77.91 | 69.04 | 2.96 | 1.16 | 26.79 | 0.05 |
MEA-AC | 10.45 | 17.42 | 0.4 | 71.73 | 68.14 | 3.55 | 7.72 | 20.32 | 0.27 |
Samples | SBET (m2/g) | νT (cm3/g) | M.P.V. (cm3/g) | Avg. pore radius (Å) | Micro pore area (m2/g) |
---|---|---|---|---|---|
RAW | 59.73 | 0.05 | 0 | 16.85 | 0 |
AC | 995.79 | 0.449 | 0.37 | 9.0119 | 921.71 |
MEA-AC | 572.27 | 0.26 | 0.21 | 9.94 | 492.72 |
In this study, CO2 was removed in a four stage fluidized bed reactor by amine impregnated activated carbon. The response surface methodology using central composite design used to determine the effect of inlet CO2 concentration (3000–20,000) ppm, impregnation ratio of adsorbent (0.2–0.6) and weir height (20–60) mm on CO2 removal efficiency (%). The regression analysis and optimization of variables has been found out by the use of statistical design expert software. A model was developed to correlate the three variables to the response. 3D response surface plot helps to describe the effect of the process variables on the CO2 removal efficiency (%). From the process optimization it was found that experimental values obtained for CO2 removal efficiency (%) are found to agree satisfactorily with the model predicted value. The optimum production conditions are initial concentration of CO2 (7312 ppm), chemical impregnation ratio (0.31) and weir height (48.65 mm) and the optimum removal efficiency was found to be 95.17%. At the same operating condition the CO2 removal efficiency was found to be 95.97% found from the experiment. The experimental value was found to agree well with that of predicted value.
[1] | Aaron D, Tsouris C (2005) Separation of CO2 from flue gas: a review. Sep Sci Technol 40(1–3):321–348 |
[2] | Adamski A, Zapala P, Jakubus P, Sojka Z (2007) Surface modification of ZrO2 nanopowder with oxovanadium species using slurry deposition and impregnation methods. J Alloys Compd 442:302–305 |
[3] | Alam MZ, Muyibi SA, Toramae J (2007) Statistical optimization of adsorption processes for removal of 2,4-dichlorophenol by activated carbon derived from oil palm empty fruit bunches. J Environ Sci 19:674–677 |
[4] | Alvim-Ferraz MCM, Gaspar C (2005) Impregnated active carbons to control atmospheric emissions: influence of impregnation methodology and raw material on the catalytic activity. Environ Sci Technol 39:6231–6236 |
[5] | Arenillas A, Smith KM, Drage TC, Shape CE (2005) CO2 capture using some fly ash-derived carbon materials. Fuel 84:2204–2210 |
[6] | Azargohar R, Dalai AK (2005) Production of activated carbon from Luscar char: experimental and modeling studies. Microporous Mesoporous Mater 85(3):219–225 |
[7] | Bai HL, Yeh AC (1997) Removal of CO2 greenhouse gas by ammonia scrubbing. Ind Eng Chem Res 36(6):2490–2493 |
[8] | Bowker M, Nuhu A, Soares J (2007) High activity supported gold catalysts by incipient wetness impregnation. Catal Today 122:245–247 |
[9] | Box GEP, Hunte JS (1957) Multi-factor experimental designs for exploring response surfaces. Ann Math Stat 28(1):195–241 |
[10] | Box GEP, Hunter WG (1961) The 2k−p fractional factorial designs, parts I and II. J Tachometer 3:311–458 |
[11] | Box GEP, Hunter WG, Hunter JS (1978) Statistics for experimenters. An introduction to design, data analysis, and model building. Wiley Series in Probability and Mathematical Statistics (USA) |
[12] | Can MY, Kaya Y, Algur OF (2006) Response surface optimization of the removal of nickel from aqueous solution by cone biomass of Pinus sylvestris. Biores Technol 97(14):1761–1765 |
[13] | Das D, Meikap BC (2017) Optimization of process condition for the preparation of amine-impregnated activated carbon developed for CO2 capture and applied to methylene blue adsorption by response surface methodology. J Environ Sci Health Part A 52:1164–1172 |
[14] | Das D, Meikap BC (2018) Comparison of adsorption capacity of mono-ethanolamine and di-ethanolamine impregnated activated carbon in a multi-staged fluidized bed reactor for carbon-dioxide capture. Fuel 224:47–56 |
[15] | Das D, Meikap BC (2019) Removal of CO2 in a multi stage fluidised bed reactor by monoethanolamine impregnated activated carbon. Miner Process Extr Metall. https://doi.org/10.1080/25726641.2019.1591791 |
[16] | Das D, Samal D, Meikap BC (2015) Preparation of activated carbon from green coconut shell and its characterization. J Chem Eng Proc Technol 6(5):1–7 |
[17] | Das D, Samal DP, Meikap BC (2016a) Removal of CO2 in a Multistage Fluidized Bed Reactor by Activated Carbon Prepared from Green Coconut Shell. Recent Advances in Chemical Engineering. Springer, Singapore, pp 133–142 |
[18] | Das D, Samal DP, Meikap BC (2016b) Removal of CO2 in a multistage fluidized bed reactor by diethanol amine impregnated activated carbon. J Environ Sci Health Part A 51:769–775 |
[19] | Das D, Samal DP, Mohammada N, Meikap BC (2017) Hydrodynamics of a multi-stage counter-current fluidized bed reactor with down-comer for amine impregnated activated carbon particle system. Adv Powder Technol 28:854–864 |
[20] | Drage TC, Arenillas A, Smith KM, Pevida C, Piippo S, Snape CE (2007) Preparation of carbon dioxide adsorbents from the chemical activation of urea–formaldehyde and melamine–formaldehyde resins. Fuel 86:22–31 |
[21] | El-Molla SA, El-Shobaky GA, Sayed Ahmed SA (2007) Catalytic promotion of activated carbon by treatment with some transition metal cations. Chin J Catal 28:611–616 |
[22] | Gönen F, Aksu Z (2008) Use of response surface methodology (RSM) in the evaluation of growth and copper (II) bioaccumulation properties of Candida utilis in molasses medium. J Hazard Mater 154:731–738 |
[23] | Gray ML, Soong Y, Champagne KJ, Baltrus J, Stevens RW, Toochinda P, Chuang SSC (2004a) CO2 capture by amine-enriched fly ash carbon sorbents. Sep Purif Technol 35:31–36 |
[24] | Gray ML, Soong Y, Champagne KJ, Baltrus J, Stevens RW Jr, Toochinda P, Chuang SSC (2004b) CO2 capture by amine-enriched fly ash carbon sorbents. Sep Purif Technol 35(1):31–36 |
[25] | Gray ML, Soong Y, Champagne KJ, Penn Line H, Baltrus JP (2005) Improved immobilized carbon dioxide capture sorbents. Fuel Process Technol 86:1449–1455 |
[26] | Hsu SC, Lu C, Su F, Zeng Chen W (2010) Thermodynamics and regeneration studies of CO2 adsorption on multiwalled carbon nanotubes. Chem Eng Sci 65:1354–1361 |
[27] | Lach J, Okoniewska E, Neczaj E, Kacprzak M (2006) Removal of Cr(III) cations and Cr(VI) anions on activated carbons oxidized by CO2. Desalination 206:259–269 |
[28] | Mahalik K, Sahu JN, Patwardhan AV, Meikap BC (2010) Statistical modelling and optimization of hydrolysis of urea to generate ammonia for flue gas conditioning. J Hazard Mater 182:603–610 |
[29] | Mohanty CR, Sivaji S, Meikap BC (2008) Hydrodynamics of a multistage countercurrent fluidized bed reactor with down comer for lime-dolomite mixed particle system. Ind Eng Chem Res 47:6917 |
[30] | Mohanty CR, Raj Mohan B, Meikap BC (2010) Identification of stable operating ranges of a counter-current multistage fluidized bed reactor with down comer. Chem Eng Process Process Intensif 49:104–112 |
[31] | Montgomery DC (2001) Design and Analysis of Experiments, 5th edn. John Wiley and Sons, New York |
[32] | Myers RH (1971) Response Surface Methodology. Allyn and Bacon, New York |
[33] | Myers RH, Montgomery DC (2002) Response surface methodology: process and product optimization using designed experiments, 2nd edn. John Wiley and Sons, USA |
[34] | Napier-Munn TJ (2000) The central composite rotatable design JKMRC. Univ Qld Brisb Aust 10:1–9 |
[35] | Plaza MG, Rubiera F, Pis JJ, Pevida C (2010) Ammoxidation of carbon materials for CO2 Capture. Appl Surf Sci 256:6843–6849 |
[36] | Przepiórski J, Skrodzewicz M, Morawski AW (2004) High temperature ammonia treatment of activated carbon for enhancement of CO2 adsorption. Appl Surf Sci 225(1–4):235–242 |
[37] | Rao AB, Rubin ES (2002) A technical, economic, and environmental assessment of Amine-based CO2 capture technology for power plant greenhouse gas control. Environ Sci Technol 36:4467–4475 |
[38] | Roy S, Mohanty CR, Meikap BC (2009) Multistage fluidized bed reactor performance characterization for adsorption of carbon dioxide. Ind Eng Chem Res 48:10718–10727 |
[39] | Sahu JN, Mahalik K, Patwardhan AV, Meikap BC (2008) Equilibrium and kinetic studies on the hydrolysis of urea for ammonia generation in a semibatch reactor. Ind Eng Chem Res 47:4689–4696 |
[40] | Sahu JN, Acharya J, Meikap BC (2009a) Response surface modeling and optimization of chromium(VI) removal from aqueous solution using Tamarind wood activated carbon in batch process. J Hazard Mater 172:818–825 |
[41] | Sahu JN, Mahalik KK, Patwardhan AV, Meikap BC (2009b) Equilibrium studies on hydrolysis of urea in a semi-batch reactor for production of ammonia to reduce hazardous pollutants from flue gases. J Hazard Mater 164:659–664 |
[42] | Sahu JN, Patwardhan AV, Meikap BC (2010) Optimization for the production of ammonia from urea in a semi-batch reactor for safe feedstock in power plants: experimental and statistical studies. CLEAN Soil Air Water 38:533–542 |
[43] | White CM, Strazisar BR, Granite EJ, Hoffman JS, Pennline HW (2003) Separation and capture of CO2 from large stationary sources and sequestration in geological formations—coal beds and deep saline aquifers. J Air Waste Manag Assoc 53(6):645–715 |
[44] | Xu X, Song C, Andresen JM, Miller BG, Scaroni AW (2002a) Novel polyethylenimine- modified mesoporous molecular sieve of MCM-41 type as high-capacity adsorbent for CO2 capture. Energy Fuels 16:1463–1469 |
[45] | Xu X, Song C, Andresen JM, Miller BG, Scaroni AW (2002b) Novel polyethylenimine-modified mesoporous molecular sieve of MCM-41 type as high-capacity adsorbent for CO2 capture. Energy Fuels 16(6):1463–1469 |
[46] | Yeh AC, Bai HL (1999) Comparison of ammonia and monoethanol amine solvents to reduce CO2 greenhouse gas emissions. Sci Total Environ 228:121–133 |
17 May 2018
28 June 2019
09 July 2019
September 2019
https://doi.org/10.1007/s40789-019-0261-6